{"product_id":"merisera-anti-d-igg-igm-10ml","title":"MERISERA® Anti-D (IgG+IgM) Blood Grouping Reagent — Dual Antibody for Weak D Detection (10ml)","description":"\u003ch2\u003eMERISERA® Anti-D (IgG+IgM) — Dual Antibody Reagent for Rh(D) Typing and Weak D Detection\u003c\/h2\u003e\n\n\u003cp\u003eMERISERA® Anti-D (IgG+IgM) is a \u003cstrong\u003eblend of monoclonal IgM and IgG anti-D antibodies\u003c\/strong\u003e for comprehensive Rh(D) blood group typing. The IgM component provides \u003cstrong\u003eimmediate spin\/slide agglutination\u003c\/strong\u003e for routine Rh typing, while the IgG component enables \u003cstrong\u003edetection of weak D (Du) variants\u003c\/strong\u003e via the indirect antiglobulin test (IAT\/Coombs test). This dual-antibody format is the \u003cstrong\u003eblood bank gold standard\u003c\/strong\u003e for complete Rh(D) determination.\u003c\/p\u003e\n\n\u003ch3\u003eWhy IgG+IgM Matters\u003c\/h3\u003e\n\n\u003cp\u003eStandard IgM-only Anti-D detects most Rh(D) positive samples but can \u003cstrong\u003emiss weak D (Du) variants\u003c\/strong\u003e — individuals with reduced D antigen expression. If mistyped as Rh-negative, these patients may receive Rh-negative blood unnecessarily (wasting a scarce resource) or, if donors, their Rh-positive units may be transfused to Rh-negative recipients causing alloimmunization. The IgG+IgM blend ensures \u003cstrong\u003eno weak D is missed\u003c\/strong\u003e — IgG antibodies sensitize weak D cells for detection by AHG in the Coombs phase.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Antibody Blend:\u003c\/strong\u003e IgM for direct agglutination (routine typing) + IgG for IAT\/Coombs phase (weak D detection)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeak D (Du) Detection:\u003c\/strong\u003e Detects partial and weak D variants that IgM-only reagents miss — critical for blood bank safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Avidity:\u003c\/strong\u003e Strong immediate agglutination on slide\/tube for routine Rh typing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Titre:\u003c\/strong\u003e ≥1:128 — reliable in both direct and indirect phases\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAABB\/DGHS Compliant:\u003c\/strong\u003e Meets blood bank regulatory requirements for complete Rh(D) determination\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree from TTI:\u003c\/strong\u003e Negative for HIV-1\/2, anti-HCV, and HBsAg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10ml Pack:\u003c\/strong\u003e Dropper bottle for routine use\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eClinical Applications\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eComplete Rh(D) typing including weak D (Du) detection in blood banks\u003c\/li\u003e\n\u003cli\u003eDonor Rh typing — ensures weak D donors are correctly classified as Rh-positive\u003c\/li\u003e\n\u003cli\u003eAntenatal Rh determination — accurate typing guides anti-D immunoprophylaxis decisions\u003c\/li\u003e\n\u003cli\u003eNewborn Rh typing in HDFN investigation\u003c\/li\u003e\n\u003cli\u003eResolution of Rh typing discrepancies\u003c\/li\u003e\n\u003cli\u003eQuality control for Rh(D) testing in transfusion services\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTesting Protocol\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetects\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmediate Spin \/ Slide\u003c\/td\u003e\n\u003ctd\u003eDirect agglutination (IgM)\u003c\/td\u003e\n\u003ctd\u003eStandard Rh(D) positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIAT \/ Coombs Phase\u003c\/td\u003e\n\u003ctd\u003eIndirect antiglobulin test (IgG)\u003c\/td\u003e\n\u003ctd\u003eWeak D (Du) variants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDGMSER-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnti-D (IgG+IgM) Blood Grouping Reagent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVolume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAntibody Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMonoclonal blend — IgM (direct) + IgG (IAT\/Coombs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecificity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnti-D (Rh₀) — routine Rh typing + weak D (Du) detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTitre\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥1:128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSlide, Tube (immediate spin) + IAT (Coombs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2–8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSN Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGST\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% (inclusive in listed price)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeril Diagnostics Pvt. Ltd., India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAnti-D IgM vs. Anti-D IgG+IgM — Which Do You Need?\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAnti-D IgM only (ANDSER-01)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAnti-D IgG+IgM (this product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoutine Rh typing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e✅ Yes\u003c\/td\u003e\n\u003ctd\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeak D (Du) detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e❌ No\u003c\/td\u003e\n\u003ctd\u003e✅ Yes (via IAT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePathology labs, rapid screening\u003c\/td\u003e\n\u003ctd\u003eBlood banks, antenatal, HDFN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e₹300\u003c\/td\u003e\n\u003ctd\u003e₹550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhy Buy From Agile Healthcare?\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eAuthorized Meril Diagnostics master distributor — genuine stock with batch traceability\u003c\/li\u003e\n\u003cli\u003eGST-inclusive pricing — no hidden charges\u003c\/li\u003e\n\u003cli\u003eVolume discounts: 10% off at 5+, 18% off at 10+, 25% off at 25+\u003c\/li\u003e\n\u003cli\u003eCold-chain compliant packaging for temperature-sensitive reagents\u003c\/li\u003e\n\u003cli\u003ePan-India delivery within 3–5 business days\u003c\/li\u003e\n\u003cli\u003eComplete MeriSera range: \u003ca href=\"\/products\/merisera-anti-a-blood-grouping-10ml\"\u003eAnti-A\u003c\/a\u003e | \u003ca href=\"\/products\/merisera-anti-b-blood-grouping-10ml\"\u003eAnti-B\u003c\/a\u003e | \u003ca href=\"\/products\/merisera-anti-d-blood-grouping-10ml\"\u003eAnti-D (IgM)\u003c\/a\u003e | \u003ca href=\"\/products\/merisera-anti-abd-blood-grouping-kit\"\u003eAnti-ABD Kit\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Meril Diagnostics","offers":[{"title":"1x10","offer_id":52011693539648,"sku":"DGNSER-01","price":550.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0962\/2231\/4816\/files\/Gemini_Generated_Image_lok9gjlok9gjlok9.png?v=1781001260","url":"https:\/\/agilehealthcare.shop\/products\/merisera-anti-d-igg-igm-10ml","provider":"My Store","version":"1.0","type":"link"}